AM Transformers Home Page AM Transformers - UK Transformer Manufacturer
SMD & SMT Power Inductors
 

 
Fig
A(Max)
B(Max)
C(Max)
D
E
F
G
H
I
TSS0603
F1
6.60
4.45
2.92
1.02
1.27
4.32
4.06
1.40
3.56
TSS1305
F2
12.95
9.40
5.08
2.54
2.54
7.62
7.37
2.92
2.79

* The nominal inductance is marked by a colour code as listed in the table below.

Colour
Nominal Inductance (µH)
First Figure
Second Figure
Magnification
Black
0
1
Brown
1
10
Red
2
100
Orange
3
1000
Yellow
4
-
Green
5
-
Blue
6
-
Purple
7
-
Grey
8
-
White
9
-
Gold
-
0.1
Silver
-
0.01
 
  TSS 0603 Type


Magnetically shielded
For high currents very low DCR & high efficiency
Flat bottom for reliable surface mounting
Reflow soldering & hand soldering are available
Good solder fillets and easy inspection
Good temperature characteristics prevents damage during solder reflow
For use at switching frequencies from 50 KHz To 1 MHz
Custom designs available

Electrical Specification

Part
Number
L±20% (M) (µH)
Q min
DCR Max
(Ohms)
SRF typ
(MHz)
Current max
(A)
1R0
1
30 @ 200 kHz
0.040
250
3.0
4R7
4.7
40 @ 200 kHz
0.060
105
1.4
6R8
6.8
40 @ 200 kHz
0.065
50
1.2
100
10
40 @ 200 kHz
0.075
38
1.0
470
47
40 @ 100 kHz
0.23
20
0.5
680
68
40 @ 100 kHz
0.29
15
0.4
101
100
40 @ 100 kHz
0.48
10
0.3

1. Inductance tested at 0.1 Vrms, 100 kHz
2. 30.c temperature rise
3. Operating temperature range -40c to +85c
4. Electrical specifications at 25c

  TSS 1305 Type


Magnetically shielded
For high current & very low DCR
Flat bottom for reliable surface mounting
Reflow soldering & hand soldering are available
Good solder fillets and easy inspection
Good temperature characteristics prevents damage during solder reflow
Custom designs available

Electrical Specification

Part
Number
L±20% (M) (µH)
DCR Max
(Ohms)
SRF typ
(MHz)
Isat2
(A)
Irms3
(A)
1R0
1
0.021
140
5.6
5.0
4R7
4.7
0.054
40
3.2
2.7
6R8
6.8
0.075
38
2.8
2.2
100
10
0.101
35
2.4
2.0
470
47
0.472
13
1.0
0.8

1. Tested at 100 kHz, 0.1 Vrms
2. Inductance drop = 10% typ. at rated Isat
3. 40c rise typ at Irms
4. Operating temperature range -40c to +85c
5. Electrical specifications at 25c
 
Link Menu
 
Home page
Products
Services
Specials
Technical support
Delivery Details
Contact us
About us
Search our site
Enquiry form
Bookmark page
Tell a friend
Site map
 
AM Transformers Home